At a glance

Utherm Floor LE is useful where the required thermal resistance must fit beneath a fixed floor level. However, the available height is not taken up by insulation alone. It is worth starting the selection from the threshold and the finished floor, then laying out the whole build-up. Utherm Floor LE is a PIR board intended for floors. It has a gas-tight laminate on both sides with a printed grid. The terms ‘polyurethane boards’ and ‘polyurethane foam’ are broader than the precise PIR product designation. When assessing the space for PIR boards, the restricted floor level at the doors in a Utherm Floor LE solution must be checked. To assess the spatial benefit, the height of Floor LE, the screed, the services and the finished covering must be added together.

Utherm Floor LE insulation board showing the core and facings

PIR Floor LE boards and the finished floor level

A full selection requires more than reading off the lambda, because the board dimension alone does not show the height of the finished floor. The selection is meant to help accommodate the required insulation without inadvertently reducing the layers above it. Before comparing variants, show on a single drawing the build-up from the substrate to the level of the threshold and the adjoining floor.

The right thickness and reading the thermal resistance

The thermal conductivity of Utherm Floor LE is 0.022 W/(m·K). Such a low lambda is useful when the space between the substrate and the finished floor is limited. The energy comparison should include the 60 mm Floor LE board, with a declared R_D of 2.70 m²K/W and a lambda of 0.022 W/(m·K).

The thermal calculation will be clear when the thermal result can be attributed to the correct Floor LE thickness. A difference in thickness requires proper interpretation, since a floor on the ground requires account to be taken of the geometry and the conditions of contact with the substrate. The calculation should allow the effect of the board to be assessed without calling its resistance the coefficient of the whole floor. Keep the catalogue data for the chosen thickness and a separate calculation of the actual build-up as the basis for the decision, rather than comparing the price of a centimetre of material alone.

Polyurethane insulation on a prepared substrate

Even support is a condition the substrate must meet. The PIR board is not intended for levelling out pronounced bumps and hollows. The continuity of the polyurethane insulation must also be maintained where the support of Floor LE needs to be resolved around conduits routed beneath the insulation.

When analysing continuity, it is worth levelling the surface beneath Floor LE boards in the 1200 × 600 mm format. The fit must be assessed for the actual geometry, because a protruding pipe or a hollow may leave the board supported at only a few points. The installation plan should achieve even contact without inadvertently wedging the insulation with offcuts. In the energy assessment, include the condition of the substrate, the levels and the way services are routed beneath the thermal layer, because these places will remain after purchasing a board with the best lambda.

Heating, screed and movement joints

With underfloor heating, the insulation reduces heat loss towards the substrate. It does not, however, replace the design of pipe spacing, flow temperature or circuit control. To preserve the thermal improvement, the heating system above Floor LE and its connection to the screed must be checked.

When assessing the durability of the effect, the separating layer, pipe fixing and movement joints above Floor LE must be agreed. The actual construction of the connection is important, because PIR reduces the flow towards the substrate but does not select the heating output or control. The layer solution should preserve the required thermal build-up without omitting the requirements of the heating part. At acceptance before covering, it is worth comparing the pipe design, screed thickness and type of room-side finish with the adopted detail.

Equipment loads and impact sound

The fact that an insulation board is rigid does not in itself mean it acts as a layer attenuating impact sound. If the floor is to meet acoustic requirements, a suitably selected system is necessary. When limiting the layer height, the heavy wardrobe and the requirement to reduce footstep sound above the Floor LE board must be assessed at the same time.

Beyond selecting the lambda, the assessment of heavy equipment must also be separated from the required acoustic function of the floor. It is worth separating these requirements, because rigid thermal insulation does not automatically replace impact-sound material. The data collected should allow the whole floor to be matched to the actual equipment and pattern of use. Alongside the thermal calculation, present the layer arrangement that distributes pressure and the edge detail at walls, so that the result relates to a usable solution.

Polyurethane insulation: the cost of a complete floor

Before buying, it is worth drawing a cross-section from the substrate up to the finished surface. Include the insulation, heating, screed, adhesive and covering. When comparing cost and effect, take into account the cost of adjusting thresholds when the thickness of Floor LE changes.

Before calculating cost-effectiveness, it is worth comparing the cost of the whole floor with Floor LE, including preparation and finishing. The cost-effectiveness calculation will be incomplete if it is overlooked that a lower board price may mean lower resistance or omitted preparatory work. The chosen variant should allow the benefit of the saved height to be assessed against the price of the whole scope. When assessing the surcharge, set out the schedule of levels, the required levelling and all materials above the insulation against the benefit obtained in the finished assembly.

A case worth considering

Where the floor is restricted by a threshold, Floor LE can help preserve the required resistance within a small height. For 60 mm, the catalogue states R_D 2.70 m²K/W. However, space must be left for levelling, services and screed. If any of these dimensions is omitted, the benefit of thin insulation will be illusory. It is worth starting the selection from the finished floor level and deducting the successive required layers.

7 branches. Materials closer to your project.

Map of seven branches offering sandwich panels, PIR boards and sheet metal — Ecoprofil
  • SEROCK — Dzierżenin 34 E [map]
  • BŁONIE — ul. Sochaczewska 138A [map]
  • RADOM — ul. Grobickiego 8 [map]
  • ŁÓDŹ — Natolin 8 [map]
  • OLSZTYN — Barczewo, ul. Prosta 9 [map]
  • WROCŁAW — ul. Jerzmanowska 10C [map]
  • GORZÓW WLKP. — ul. Zielona 33/34 [map]

Check prices and availability: +48 500 409 109

Free quote

Materials for your project

You may also find useful…