Choosing BauderPIR M or MF takes more than a lambda value of 0.022
The same PIR thickness appears in two quotes, but one board has an aluminium facing and the other a mineral fleece. The prices look similar, so the difference in parameters is easily overlooked. In the M/MF variant, you have to go back to the correct lambda. Only then will the comparison show whether both proposals provide a similar thermal resistance at the same thickness. The starting point is a roof with a PIR board with a mineral facing. Here a particular constraint is the requirement that the mineral facing be compatible with the adopted system. The design must establish the correct lambda and a compatible connection to the waterproofing, not merely fit in another sheet. The area requiring attention is the fleece zone beneath the waterproofing layer.

In this article
Constraint first, then thickness
A set of documents for the specific M or MF thickness and for the connection with the covering will be needed, since the view of the flat field alone does not show all heights. When buying BauderPIR M/MF, it is worth agreeing this part first, before the thickness becomes an assumption for the remaining works.
The correct product and the scope of its data
A PIR core and mineral fleece on both sides make up the construction of BauderPIR M/MF. The family has a format of 1200 × 600 mm, and M and MF differ in edge profile. The Polish M data sheet gives λD 0,026 W/(m·K) for 80 mm up to below 120 mm, so this is not a constant lambda of 0,022. The documentation indicates at least 120 kPa in the compression test and fire reaction E. Bauder PIR boards should here be assessed for the range that is a roof with a PIR board in mineral facing. When checking an order, the term polyurethane boards does not replace the full name BauderPIR M/MF. In BauderPIR M/MF, polyurethane foam of the PIR type forms the core, and the properties of the complete board also include its facings.
What the figures show in this case
Whether the mineral facing is compatible with the roof system is part of selecting BauderPIR M/MF. Compare insulation depths once a suitable board has been identified. At R = 4.00 m²K/W and λ = 0.026 W/(m·K), the required thickness is about 104.0 mm. A comparison board assigned λ = 0.036 would reach that resistance at 144.0 mm. Both thicknesses come from multiplying R by λ. Specify the actual M/MF board from its documentation. The hypothetical conductivity used here is not a product specification.
In the example concerning BauderPIR M/MF, the figures describe only the indicated part of the task. Their use makes sense together with a measurement that covers the thickness of the insulation to be ordered and the condition of the substrate beneath the covering. The property relevant to the comparison is the lambda dependent on the thickness of the M variant. In this arrangement, the correct thickness range in the document for the ordered variant must also be read. Only then does the document set for the specific M or MF thickness and the connection to the covering allow the result to be related to the actual section. The energy calculation should retain the same scope also when comparing with another thickness of BauderPIR M/MF.
Two directions for improvement
The first direction is to retain the designed facing and select the required thickness. The second is to change the entire verified assembly after a renewed comparison. The scope of both actions depends on how important the fleece zone beneath the waterproofing layer is. In the variant with BauderPIR M/MF, the cost of the entire surface should not be increased before the local constraint has been identified. A trap would be to calculate the board with mineral facing using the lambda of the aluminium variant, even if the result for the main field looks favourable. The comparison is only closed when the schedule of parameters covering thickness, facing and edge also includes the differences caused by changing the variant.
A connection that must preserve the effect
The design should clearly specify the plain profile in M or the milled profile in MF. In the description of BauderPIR M/MF, it is worth separating its geometry from the tightness of the other layers. The product surface is formed by a matt mineral fleece, but its presence does not automatically solve the entire detail. What is needed for checking is a description of the fleece on both surfaces and of the correct edge profile. The next stage will be a waterproofing covering compatible with the mineral facing, so the error should not be shifted onto the installer of the next layer. It is worth recording at acceptance how the fleece zone beneath the waterproofing layer was executed and why this method was chosen.
The cost of achieving the same function
The BauderPIR M/MF quotation should be related to the completed task, not to a single favourable parameter. The calculation should include a schedule of parameters covering thickness, facing and edge. A separate cost may arise from the need for a level substrate beneath the board with undamaged fleece. It is also worth pricing the work at the detail described as the fleece zone beneath the waterproofing layer. The differences should be explained by the specialist approving the compatibility of the insulation with the covering, so that the saving does not result from removing a necessary layer. Insulation compared in this way corresponds to the actual effect that the roof with PIR board in a mineral facing is to deliver.
The condition for a justified decision
The selection can be regarded as orderly when the correct lambda and a compatible connection to the covering have been established. For BauderPIR M/MF, this means combining the material data with the solution for the perimeter and the other layers. The document to be retained is the document set for the specific M or MF thickness and the connection to the covering. It should be accompanied by a description of the fleece on both surfaces and of the correct edge profile, so that a later renovation does not begin with guessing the product. There is no need to add a promise of a quick return without a building balance. If the condition that the mineral facing must be compatible with the adopted system changes, it is necessary to return to the comparison instead of copying the previous thickness. Polyurethane insulation has a specific purpose here: to establish the correct lambda and a compatible connection to the covering.
7 branches. Materials closer to your project.

Free quote
Materials for your project
You may also find useful…
The properties of swissporPIR Alu must be preserved along the entire route from delivery to the closing of the layers. The condition…
SIP panels allow several tasks to be combined in a single prefabricated component. A rigid insulating core sits between two facings. Such…
An internal ceiling can separate a heated or climate-controlled room from the roof void. In a cattle shed or warehouse, its appearance…
The answer to the question of insulating a loft before installing the lining comes down to the correct sequence of work and…
An aluminium facing on a PIR board can greatly restrict water vapour diffusion. The performance of the finished wall depends on how…
Indoor moisture conditions depend on how much water vapour is produced, how the house is ventilated and how warm its surfaces are.…
After ALU TG has been laid, the regular field looks tight. At the perimeter, however, cut pieces without the full factory profile…
The life of insulation depends on the product, its service conditions and how the installer forms the junctions. Before adding insulation, repair…